  • Flashing
     
    Possible Fault Cause Solution

    Incorrect Water or Powder Ratio

    Ensure Correct Ratio P:W
    Conventional Mix 40:100
    Vacuum Mix 38:100

    Incorrect Burnout Cycle

    Follow recommended burnout cycle.
    Ensure furnace ramp does NOT exceed 250¨¬C/Hr.
    Ensure 1st stage burnout does NOT exceed 240¨¬C and is held for 4.5 hours minimum. If problem still occurs increase hold time.

    Excessive Casting Forces

    Centrifugal casting: Lower torque and RPM settings.
    Vacuum casting: Reduce over pressure.

    Disturbed Flask during setting

    After investing bench set and do NOT move flask, strip base or remove tape for a minimum of 90 minutes.

    Over working investment

    Ensure all flasks are poured and removed from vacuum tank and put on bench to set by max. 9 minutes from starting mixing.

    Waxes too close

    Waxes too close together creating a very thin wall of investment. Waxes too close to side or top of flask; ensure min. 5mm gap to top and sides of flask.

    Slurry too hot or cold

    Adjust slurry temperature to 21¨¬C +/- 1¨¬C by increasing or decreasing water temperature.

    Moulds dried out before burnout

    If flasks are left on bench for more than 4 hours before burnout place a damp towel over the tops of the flasks to stop them drying out. Do NOT leave flasks in furnace overnight before burnout.

    Flask base leak during investing

    Ensure good seal between wax sprue and base. It is suggested that it be sealed with molten wax.

     
  •